Skip to content
Aeonis LeakThe checkWhere it goesFixes that payRenters & ownersPricing

Method

Everything here is a simplified estimate. Change any input in the check to fit your home.

Prices

If you enter a bill amount and its kWh (or therms), we divide them to get your real rate. Otherwise we use your state's average from the U.S. EIA (see sources).

Heating and cooling

Heat loss = floor area × a loss factor (0.35, 0.25 or 0.15 Btu/h per ft² per °F for leaky, average or tight homes; our assumption) × degree days × 24 h. Degree days use NASA POWER's 18.3°C (65°F) base. Gas furnaces are taken at 80% efficiency, electric resistance at 100%, existing heat pumps at HSPF2 7.5, existing air conditioners at SEER2 13.4.

Fixes

What it doesn't do

It isn't an energy audit, a blower-door test or a quote. It doesn't know your utility's tariff details, time-of-use rates or net-metering rules, and it doesn't include incentives.